Is ice and water shield required in Pennsylvania

Ice and water shield is required on any “A” framed roof from the eave to a point 2′ inside the wall line. There is an exception for detached accessory structures not intended to be habitable spaces.

Is ice and water barrier required?

Because of its importance, every roof needs to have it. There’s also a code if you live in an area above the snow line in the US. This code requires ice and water shield along the edges of your roof to prevent leaking from ice damming after a heavy snow or ice storm.

What building codes does PA use?

These pages provide information regarding Pennsylvania’s statewide building code, generally known as the Uniform Construction Code (UCC).

Should I use ice and water shield on my whole roof?

In areas where the risk of either ice dams or wind-driven rain is severe, it is sometimes recommended, or mandatory, to install ice and water protector over the entire roof, regardless of pitch.

What IBC does Pennsylvania use?

Building Code 2015 of Pennsylvania based on the International Building Code 2015 (IBC 2015)

How long is a roll of ice and water shield?

Roll length75 ft (22.9 m)66.6 ft (20.2 m)Roll width36 in (914 mm)36 in (914 mm)Roll size225 ft2 (20.9 m2)200 ft2 (18.6 m2)PackagingCorrugated cartonsCorrugated cartonsRoll weight61.4 lbs (27.9 kg)55 lbs (24.9 kg)

Where should ice and water shield be installed?

  1. On the eaves of your home up to 24″ inside the exterior wall (this usually means at least 2 rows or 6 feet)
  2. In every valley (1 row or 3 feet)
  3. Around every pipe before the flashing is installed.
  4. Along every wall, chimney, or skylight where flashing will be installed.

Can you put ice and water shield over existing shingles?

No, you can’t apply it on top of the old shingles. You must apply this product as indicated by the manufacturer. Typically you’ll discover that you must apply the material directly to the wood roof sheathing that’s under the shingles and any old felt paper.

Does tar paper go over ice and water shield?

Method 1: Install the ice-barrier membrane according to the manufacturer’s instructions with the drip edge installed on top of the membrane. Then install regular roofing underlayment (tar paper) over the top of the drip edge (and over the ice barrier) and continuing all the way up the roof.

Does ice barrier go under drip edge?

The best way is to install the roof drip edge only along the eaves first, then place ice-and-water barrier (in the snowbelt) or felt paper (underlayment) over the drip edge. This lets any water that gets on the roof run down the underlayment and over the drip edge.

Article first time published on

Do you need a permit to do siding in PA?

However, generally you will not need a permit for any finishing work such as painting, carpeting, and tiling, nor will you need a permit for ordinary repairs. Depending on where you are, you may not need to get a permit for fences, small swimming pools, hanging gutters, roof replacement, siding, and drywall repairs.

How big of a shed can I build without a permit in PA?

For example; the PA UCC exempts fully-detached residential accessory buildings (garage or shed) less than 1000 square feet from needing a permit, but many jurisdictions have amended this provision to reduce the exemption to two-hundred (200) square feet.

Do I need a building permit PA?

A residential building permit is required for the following work on a residential building or structure: Renovate and repair an existing single-family or two-family dwelling. Construct an addition to an existing single-family or two-family dwelling.

What energy code does Pennsylvania use?

The PA UCC first took effect on April 9, 2004 with the adoption and use of the ICC’s International Codes 2003. Effective December 31, 2006, the International Codes 2006 were adopted and enforced throughout Pennsylvania.

How deep should a PA footer be?

Footers must be a minimum of 24 inches deep. There must be a minimum of 6 inches of concrete in the footer, 2 story home-8 inches deep. wide). Rebars are required in dwellings.

Do you need a permit for a deck in PA?

A Building Permit is required for a deck where the floor surface is greater than 30 inches above grade at any point. … The footings must be a minimum of 36 inches below grade.

Do you staple down ice and water shield?

Do not staple or nail the shield unless it is absolutely needed. Overlap the first line with the second line. The overlapped area should be three inches. Remove the back and adhere it to the roof.

Can you nail through ice and water shield?

When nails penetrate the ice and water shield on the roof, the rubberized nature of the material creates a gasket effect on the shaft of the nail. … Not only does ice and water shield stop leaks caused by ice dams, but it also stops leaks created by fierce wind-driven rain.

How much do you overlap ice and water shield?

3. Minimum overlap guidelines are set by the manufacturer. Grace requires side laps to be a minimum of 3.5 in. and end laps a minimum of 6 in.

How much does a roll of ice and water shield cost?

current product$19362 /roll$14047 /roll$15463 /roll(255)(53)(35)

How much does ice Guard cost?

Ice dam Barrier CostsZip CodeSquare ft.BasicBetterIce dam Barrier – Installation Cost$220.00 – $240.00$265.00 – $280.00Ice dam Barrier – Total$385.00 – $415.00$455.00 – $490.00Ice dam Barrier – Total Average Cost per square ft.$4.00$4.72

How do you remove ice and water shield from roof?

Sometimes shingles come off the ice shield better when it is hot. In that case, let the area heat up a bit and then tear that area off, and then the shingles will separate from the ice shield. Sometimes shingles just won’t come up at all.

Do you install drip edge before fascia?

The correct placement of a roof drip edge is on top of the roof’s exterior cover directly between the sheathing and the fascia board, which forms a drainage gap between the drip edge and the fascia board. As a result, the drainage improves water flow and protects the roof from potential water damage.

Do you need felt paper over ice and water shield?

Tim wrote in asking if he should use roofing paper on his roof in addition to Ice and Water shield. … It is not absolutely necessary but it is extra protection over that area of the roof that could potentially have water backing up from roof edge ice dams, up and under the shingles.

Is metal drip edge required by code?

The IRC now requires a drip edge for all asphalt roof installations and provides direction for its proper installation. Underlayment must lap over the drip edge at the eaves. At the rake edges (the sloped edges that are referred to as “gables” in the code text), the drip edge must be installed over the underlayment.

Can Grace Ice and water Shield be left exposed?

GCP’s underlayments (GRACE ICE & WATER SHIELD®, GRACE ICE & WATER SHIELD® HT, GRACE ULTRA™, GRACE SELLECT™, GCP granular underlayment, Roof Detail Membrane™, TRI-FLEX® and TRI-FLEX® 15) are not meant to be left permanently exposed to the sun.

Is ice and water shield breathable?

In terms of breathability, they are similar to 30-pound roofing felt. Most ice and waterproofing membranes have good life expectancies once they are protected from UV. … They are not self-sealing underlayments and are installed in a similar fashion as 30-pound roofing felt.

Does drip edge go under tar paper?

The drip edge should be over the paper at the eaves, and under along the rake. mroberson: Its a TRAP! Back in my construction days, I learned that you place the tar paper OVER the drip edge on the eaves so if moisture gets through the shingles, it does not get under the drip edge.

Should you use drip edge touch fascia?

A vertical drip edge lip extends down roughly 1 5/8″ and as Steve points out, should not be set tight against the fascia board or water may run behind the gutter and down the fascia, inviting leaks and rot.

Do you need a permit to replace a water heater in Pennsylvania?

The simple answer is the permit is required so that an inspection can be done to make sure the water heater is installed properly, and that it does not create a hazard to the building occupants.

Do you need a permit for a patio in PA?

Yes, a Zoning Permit is required to construct a concrete slab or paver patio.